> Where can I find a list of the advanced AT commands (AT&
> commands)? My modem's defauat configeration has several which I have no
> clue as to what they mean.
If you have a USRobotics, typing AT&$ will give you a help screen.
Otherwise, the manual should have a list.
Here's the screen my from my Courier, most commands should be the same.
-----8<--- cut here -------- cut here -------- cut here -----8<-----
AT&$
HELP, Ampersand Commands (CTRL-S to Stop, CTRL-C to Cancel)
&An n=0 Disable /ARQ Result Codes &Pn n=0 N.American Pulse Dial
n=1 Enable /ARQ Result Codes n=1 UK Pulse Dial
n=2 Enable /Modulation Codes &Rn n=0 CTS Follows RTS
n=3 Enable /Extra Result Codes n=1 Ignore RTS
&Bn n=0 Floating DTE Speed n=2 RX to DTE/RTS high
n=1 Fixed DTE Speed &Sn n=0 DSR Always On
n=2 DTE Speed Fixed When ARQ n=1 Modem Controls DSR
&Cn n=0 CD Always On n=2 Pulse DSR, CTS=CD
n=1 Modem Controls CD n=3 Pulse DSR
&Dn n=0 Ignore DTR n=4 DSR = DCD
n=1 On-Line Command Mode n=5 Modem Controls DSR, CTS=CD
n=2 DTE Controls DTR &Tn n=0 End Test
&Fn n=0 Load Factory Configuration n=1 Analog Loopback (ALB)
n=1 Hardware Flow Control Cnfg. n=3 Digital Loopback (DLB)
n=2 Software Flow Control Cnfg. n=4 Grant Remote DLB
n=3 HST/Cellular w/ HW FC Cnfg. n=5 Deny Remote DLB
&Gn n=0 No Guard Tone n=6 Remote Digital Loopback
n=1 550 Hz Guard Tone n=7 Remote DLB With Self Test
n=2 1800 Hz Guard Tone n=8 ALB With Self Test
&Hn n=0 Disable TX Flow Control &W Store Configuration
n=1 CTS &Xn n=0 DCE Synchronous Clock
n=2 Xon/Xoff n=1 DTE Synchronous Clock
n=3 CTS and Xon/Xoff n=2 RX Clock is Source
&In n=0 Disable RX Flow Control &Yn n=0 Destructive
n=1 Xon/Xoff n=1 Destructive/Expedited
n=2 Xon/Xoff Chars Filtered n=2 Nondest./Expedited
n=3 HP Enq/Ack Host Mode n=3 Nondest./Unexpedited
n=4 HP Enq/Ack Terminal Mode &Zn=s Store Phone Number
n=5 Xon/Xoff for non-ARQ Mode &Zn=L Store Last Phone Number
&Kn n=0 Disable Data Compression &Zn? Query Phone Number
n=1 Auto Data Compression
n=2 Enable Data Compression
n=3 Selective Data Compression
&Ln n=0 Disable Leased Line
n=1 Enable Leased Line
n=2 Enable Cellular
&Mn n=0 Normal Mode
n=1 Synchronous Mode
n=4 ARQ/Normal Mode
n=5 ARQ Mode
n=6 V.25bis
n=7 V.25bis HDLC
&Nn n=0 Highest Link Speed
n=1 300 bps
n=2 1200 bps
n=3 2400 bps
n=4 4800 bps
n=5 7200 bps
n=6 9600 bps
n=7 12000 bps
n=8 14400 bps
n=9 16800 bps
n=10 19200 bps
n=11 21600 bps
n=12 24000 bps
n=13 26400 bps
n=14 28800 bps
n=15 31200 bps
n=16 33600 bps
OK
-----8<--- cut here -------- cut here -------- cut here -----8<-----
Hope that helps...
--